Skip to main content

Serial to LoRa 206P

Echolo Serial to LoRa 206P

The EL-ILD-206P is a half-duplex LoRa serial server that supports point-to-point protocol and has a working frequency band of 902-928MHz US Only. EL-ILD-206P transmits/receives data by serial, and it can be used for both one-to-one or one-to-many communication

  1. Serial to LoRa Conversion happens automatically

  2. Long Range up to 2 Miles

  3. RS485 and RS232 with EMC High-level protection.

  4. Supports point-to-point protocol and fixed-point transmitting mode.

  5. Incoming data profile configuration is required with the Echolo Team.

Technical Specifications

Mounting

Wall Mount / Rivet Mount

Power Interface

5v to 36v DC

Working current

Transmitting current: 45mA@12V. Standby mode: 12mA@12V

Data interface

  • Serial port: RS232/RS485.

  • Baud rate: 1200bps~115200bps

LoRa

  • LoRa 915 US

  • LoRa distance: 2 Miles

  • Bi-directional Communication

Size

6.2 x 3.5 x 2.5 in

Environmental

  • Temperature: -30C to +80C

  • Humidity: 10% to 90%

Warranty

  • 2-year limited warranty (As

stand-alone Device)

  • Lifetime limited warranty (When paired

with active Echolo LoRa Subscription

Working temperature

-30℃ - +80

Transmission distance

Up to 2 Miles @ 20dBm 5dBi gain

Quick Start

Work Mode

The S2L 206P supports three work modes:

  1. AT command mode

  2. Transparent transmission mode

  3. Fixed-point transmitting mode

Length of single data package can’t exceed 252 bytes in all three work modes, otherwise, the package will be discarded.

AT command mode

In AT command mode, the user can send AT commands to query/set S2L 206P parameters by serial. 

Transparent transmission mode

In the transparent transmission mode, the data transmission process won’t influence data content. Two LoRa device can realize data transmission without any data transport protocol. To realize transparent transmission, both sides of communication must satisfy three conditions:

  1. Same rate level

  2. Same channel

  3. Same destination address or use broadcast address.

Configuration Commands

Command

Function

WMODE

Query/Set work mode

SPD

Query/Set rate level 

CH

Query/Set channel

ADDR

Query/Set destination address\

Fixed-point transmitting mode

In the fixed-point transmitting mode, S2L 206P can change destination address and channel flexibly when S2L 206P is transmitting data. Based on transparent transmission, the first two bytes of transmitted data will be destination address( High-order in the former) and the third byte of transmitted data will be a channel, and S2L 206P can change destination address and channel before transmitting and reset to original settings after transmitting.

Configuration Commands

Command

Function

WMODE

Query/Set work mode

SPD

Query/Set rate level

AT command return codes

Return Code

Description

OK

Successful response

ERR-1

Invalid command format

ERR-2

Invalid command

ERR-3

Invalid operator

ERR-4

Invalid parameter

ERR-5

Operation is not allowed

Files